>> Products Specification
>> Product Characteristic
  • Non-destructive tests using infrared rays.
  • Lightweight, low power consumption: Ideal as a portable or wall-type instrument.
  • Fast response, high sensitivity, minimum drift and optimal steadiness.
 
>> Product Applications
  • Indoor air quality monitoring such as living room, study room, bedroom and basement.
  • Closed-space air quality monitoring, such as air conditioned buildings, conference rooms and offices.
  • Energy saving when used with air conditioning systems inair terminals, subway systems and playgrounds.
  • Monitoring and control of flue and waste gas emission, such as soda plants.
  • Green house, agriculture, fishery cultivate farm¡Bair quality monitor.
 
>> Product Specification
Specifications
A-100
C-100
D-110
Examine Item
CO2
CO2
CO2
Operation Principle
Non-dispersive Infrared (NDIR)
Standard Warm-up Time
40 seconds
¡Ø1min
¡Ø1min
Standard Operating Temperature
0¢J~50¢J
0¢J~50¢J
0¢J~50¢J
CO2 Measurement Range
0~3000/6000/10000ppm
0~3000/10000
0~2000/10000
Temperature Measurement Range
0¢J~50¢J
0¢J~50¢J
Storage Temperature Range
0¢J~70¢J
-30¢J~70¢J
-30¢J~70¢J
Sensor Life Expectancy
10 years
10 years
Operating Humidity Range
0~95% RH (non-condensing)
Sampling Method
diffusion
diffusion
diffusion
Display Method
LCD
LCD
Power Input
DC.5V
24VDC
12VDC
Power Input
80mA (average)
50mA (average)
Electrical Connections
RJ-45
PCB terminal Block
PCB terminal Block
Battery
DC 1.2V.1800mA,AA*4
Option
RS-232 Transmission lineAlarm(85db buzzer)
Calibration KeypadRS-232 or RS-485 Transmission lineAlarm(85db buzzer)
Serial Interface
RS-232 or RS-485 Transmission line
Dimensions
17cmx8.5cmx5cm
15cm¡Ñ5cm¡Ñ4cm
5.5cm¡Ñ5.1cm¡Ñ2.5cm
 
Reference Technical Information
A-100
C-100
D-110
CO2 Sampling Frequency
2.8 times /sec.
Response Time (90%)
13 sec.
<5min
<5min
Reproducibility
¡Ó1%FS
Zero/Gauge Drift
¡Ó1.5%F.S
Linear Instability
¡Ó1.44%F.S
CO2 Measurement Accuracy
¡Ó3.5%F.S
¡Ó3.5%FS(3000ppm)
¡Ó5% Full Scale
¡Ó5%FS(10000ppm)
Temperature Measurement Accuracy
¡Ó1.0¢J Full Scale
CO2 Output Voltage (Linear)
0~3V
Voltage¡G0~10 VDC/0~5 VDC/1~5 VDC/2~10 VDCCurrent¡G0~20mA/4~20mA
0~2.4V
Temperature Output Voltage (Linear)
Voltage¡G0~10 VDC/0~5 VDC/1~5 VDC/2~10 VDCCurrent¡G0~20mA/4~20mA
CO2 Control Signal Output
0V,5V
Temperature Control Signal Output
PC Transmission
RS-232
RS-232 or RS-485
RS-232 or RS-485
 
------------------------------------------------------------------------------------------
561, Chung Cheng Rd., Wu Fong, Taichung Hsien, Taiwan ZIP 413
Contact person:Te Yu Shen / Tel: 04-23397711*500 / Fax:886-4-23326740 / http:// www.kingcan.com.tw
e-mail: